This manual provides comprehensive guidance for installing‚ operating‚ and maintaining the SL-2000-P duct smoke detector‚ ensuring optimal performance and compliance with safety standards.

Purpose and Scope of the SL-2000-P Manual

The SL-2000-P manual is designed to provide detailed instructions for the installation‚ operation‚ and maintenance of the SL-2000-P duct smoke detector. It serves as a comprehensive resource for technicians‚ engineers‚ and installers to ensure proper setup and functionality.

The manual covers technical specifications‚ wiring guidelines‚ troubleshooting‚ and compliance requirements. Its purpose is to guarantee the detector operates efficiently‚ meeting safety standards and regulatory demands. By following this guide‚ users can optimize performance and ensure reliable smoke detection in HVAC systems.

Overview of the SL-2000-P Duct Smoke Detector

The SL-2000-P is a cutting-edge duct smoke detector designed for early detection of smoke and combustion products in HVAC systems. It operates seamlessly in duct widths from 12.0 to 10.0 inches and air velocities of 100-4000 fpm‚ ensuring reliable performance across various environments. The detector supports both ionization and photoelectric sensing‚ offering flexibility for different applications.

With its 50/60 Hz operating frequency‚ the SL-2000-P is globally compatible and suitable for installations worldwide. It features interchangeable detector heads‚ remote accessories‚ and a robust design to meet diverse safety and regulatory requirements‚ making it a versatile solution for commercial and industrial settings.

Key Features and Benefits of the SL-2000-P

The SL-2000-P offers global compatibility‚ multiple input voltage options‚ and interchangeable detector heads‚ ensuring reliable smoke detection across various duct sizes and air velocities.

Operating Frequency and Global Compatibility

The SL-2000-P operates at 50/60 Hz‚ ensuring compatibility with diverse power grids worldwide. This adaptability allows the detector to function seamlessly in global installations‚ making it suitable for a wide range of applications and environments. Its universal frequency support enhances reliability and performance across different regions‚ eliminating the need for additional configurations or adjustments. This feature underscores its versatility and suitability for international use‚ ensuring consistent smoke detection capabilities regardless of local power standards.

Input Voltage Options and Detector Types

The SL-2000-P supports multiple input voltages‚ including 24 VAC‚ 24 VDC‚ 115 VAC‚ and 230 VAC‚ offering flexibility for various electrical systems. It features two detector types: the SL-2000-P with a photoelectric sensor for detecting larger smoke particles and the SL-2000-N with ionization technology for faster response to smaller particles. Both models ensure reliable smoke detection‚ catering to different environmental and application needs‚ while their universal voltage compatibility simplifies installation across diverse power systems globally.

Relay Contact Ratings and Air Velocity Parameters

The SL-2000-P features relay contact ratings of 10A at 115VAC resistive‚ ensuring reliable switching for connected devices. It operates effectively in ducts with air velocities ranging from 100 to 4000 feet per minute (0.5 to 20.3 meters per second). This wide range accommodates various HVAC system requirements‚ making the detector suitable for diverse applications. Proper alignment with air velocity parameters ensures accurate smoke detection and optimal performance in different environmental conditions.

Installation Requirements and Guidelines

The SL-2000-P must be installed in ducts with widths ranging from 12 inches to 10 feet and air velocities between 100 and 4000 fpm for optimal performance.

Duct Width and Air Velocity Considerations

The SL-2000-P is designed for ducts with widths ranging from 12 inches to 10 feet‚ ensuring compatibility with various HVAC systems. Proper installation requires maintaining air velocities between 100 and 4000 feet per minute (fpm) to ensure accurate smoke detection. Exceeding these limits may compromise performance. Installers must verify duct dimensions and airflow rates before mounting the detector. Correct placement ensures reliable operation and compliance with fire safety standards‚ while improper installation could lead to false alarms or reduced sensitivity. Always follow manufacturer guidelines for optimal functionality.

Wiring Instructions for Proper Connectivity

Proper wiring is essential for the SL-2000-P to function correctly. Use 14 to 22 AWG wires for connections‚ ensuring all terminals are securely fastened. The detector supports multiple voltage inputs: 24 VAC‚ 24 VDC‚ 115 VAC‚ or 230 VAC. Connect the power supply to terminals 1 and 2‚ and alarm contacts to terminals 9 and 10. For interconnection‚ link up to 30 units using form C relays. Verify wiring with a multimeter before powering up. Incorrect connections can lead to malfunction or damage. Always refer to the manual for specific wiring diagrams and safety precautions to ensure reliable operation and compliance with electrical standards.

Maintenance and Troubleshooting

Regularly clean the detector head with compressed air to ensure optimal performance. Replace heads using models 55000-328APO for the P model. Troubleshoot power issues by checking terminals 9 and 10 for 24V. Verify proper seating of the detector head and connections to avoid false alarms or malfunctions. Refer to the manual for detailed troubleshooting steps and maintenance schedules to ensure reliable operation and compliance with safety standards.

Cleaning and Replacing Detector Heads

Clean the detector head periodically using compressed air to remove dust and debris. For replacement‚ order model 55000-328APO for the SL-2000-P or 55000-225APO for the SL-2000-N. Ensure the head is properly seated after installation. Regular maintenance ensures optimal performance and prevents false alarms. Always follow the manufacturer’s guidelines for cleaning and replacement procedures to maintain reliability and compliance with safety standards.

Common Issues and Solutions for SL-2000-P

Common issues include faulty detector heads‚ improper wiring‚ or incorrect air velocity settings. Troubleshoot by checking power supply‚ ensuring terminals 9 and 10 have 24V‚ and verifying the detector head is seated. For persistent problems‚ consult the troubleshooting section or contact technical support. Regular maintenance‚ such as cleaning with compressed air‚ can prevent many issues. Refer to the manual for detailed solutions and ensure all installations meet specified guidelines for optimal functionality and reliability.

Technical Specifications

The SL-2000-P operates on 24 VAC‚ 24 VDC‚ 115 VAC‚ or 230 VAC‚ with a frequency of 50/60 Hz‚ ensuring global compatibility. Dimensions are 11.06 x 18.13 x 4.38 inches‚ weighing 28.1 lbs‚ and it functions in temperatures from 32°F to 100°F (0°C to 38°C) with a humidity range of 0-95% non-condensing.

Voltage and Power Requirements

The SL-2000-P operates on multiple voltage options‚ including 24 VAC‚ 24 VDC‚ 115 VAC‚ and 230 VAC‚ ensuring compatibility with various power systems. It consumes 3.0 VA of power and supports a frequency of 50/60 Hz for global use. The detector is designed to function within a temperature range of 32°F to 100°F (0°C to 38°C) and a humidity range of 0-95% non-condensing. These specifications ensure reliable performance across diverse environmental conditions‚ making it suitable for worldwide installations while maintaining optimal functionality and energy efficiency. Its dual voltage capability further enhances its flexibility for different applications.

Temperature and Humidity Range

The SL-2000-P operates effectively in temperatures ranging from 32°F to 100°F (0°C to 38°C) and humidity levels up to 95% non-condensing. This ensures reliable performance in various environmental conditions‚ from cool to warm climates‚ without compromising detection accuracy. Its robust design withstands typical HVAC duct conditions‚ maintaining consistent operation and longevity of the detector. Proper installation within these ranges is crucial to ensure optimal functionality and compliance with safety standards‚ while avoiding potential damage from extreme environmental factors.

Dimensions and Weight of the Detector

The SL-2000-P detector measures 11.06 x 18.13 x 4.38 inches (28.1 x 46.0 x 11.2 cm) and weighs approximately 3-4 pounds‚ ensuring compact and lightweight installation. Its durable enclosure is designed for long-term reliability‚ fitting seamlessly into standard HVAC systems while maintaining ease of access for maintenance. These dimensions and weight facilitate straightforward installation without adding significant bulk to the duct system.

Accessories and Compatibility

The SL-2000-P supports remote accessories like MSR-Series annunciators‚ WP-2000 weatherproof enclosures‚ and TG-2000 aerosol test kits‚ ensuring enhanced functionality and system compatibility.

Remote Accessories and Annunciators

The SL-2000-P is compatible with MSR-Series remote accessories‚ which offer advanced monitoring and control. These include LED indicators for alarm‚ pilot‚ and trouble statuses‚ as well as programmable buzzers for alerts. The system supports key-operated test/reset functionality and push-button testing for LEDs and buzzers. Remote annunciators provide visual and audible notifications‚ ensuring timely responses to system events. These accessories enhance the detector’s functionality‚ enabling seamless integration into larger systems while maintaining reliability and ease of use.

Sampling Tubes and Test Kits

The SL-2000-P supports various sampling tubes‚ including STN-1.0 (for ducts up to 12″)‚ STN-2.5 (6″ to 2.5″)‚ STN-5.0 (2.5″ to 5″)‚ and STN-10.0 (5″ to 10″). These tubes ensure accurate smoke detection across different duct sizes. Additionally‚ the TG-2000 aerosol test gas is available for testing detector sensitivity‚ ensuring proper functionality. These accessories are essential for maintaining system accuracy and compliance with safety standards‚ providing reliable operation in diverse HVAC applications.

Applications and Approvals

The SL-2000-P is ideal for HVAC systems‚ commercial buildings‚ and industrial ducts‚ ensuring smoke detection compliance with global safety standards and regulations.

Suitable Installations and Certifications

Suitable Installations and Certifications

The SL-2000-P is designed for installation in HVAC ducts‚ including supply‚ return‚ and exhaust systems‚ ensuring early smoke detection in air moving through ductwork. It is UL and cUL listed‚ meeting stringent safety standards for fire protection systems. The detector is suitable for duct widths ranging from 12″ to 10′ and air velocities from 100 to 4‚000 fpm. Its NEMA Type 3R enclosure ensures durability in outdoor environments. Certified for global use‚ the SL-2000-P complies with regulatory requirements‚ making it a reliable choice for commercial and industrial applications.

Regulatory Compliance and Industry Standards

The SL-2000-P is UL and cUL listed‚ ensuring compliance with North American fire safety standards. It meets NFPA 90A and 92 requirements for smoke detection in HVAC systems. The detector is designed to comply with global regulatory standards‚ including CE and EN certifications. Its NEMA Type 3R enclosure ensures durability in harsh environments. By adhering to these industry standards‚ the SL-2000-P provides reliable smoke detection‚ meeting the demands of commercial and industrial fire safety systems worldwide. Its compliance ensures seamless integration into existing fire protection infrastructures.

The SL-2000-P manual serves as a comprehensive guide for installation‚ operation‚ and maintenance‚ ensuring reliable performance and compliance with global fire safety standards;

Final Thoughts on the SL-2000-P Manual

The SL-2000-P manual is an essential resource for professionals‚ offering detailed insights into installation‚ operation‚ and maintenance. It ensures compliance with safety standards‚ providing reliable performance across various applications. The manual’s clarity and thoroughness make it a valuable tool for technicians and installers‚ guaranteeing the detector operates efficiently in diverse environments. By adhering to the guidelines‚ users can maintain safety and reduce risks associated with fire hazards in HVAC systems. This comprehensive guide underscores the importance of proper setup and ongoing maintenance for optimal functionality;