The Pro 1 T705 is a programmable thermostat designed for ease of use and reliability. It features a large LCD display‚ 5/1/1 or 7-day scheduling‚ and a 5-year warranty for optimal performance and convenience.

1.1 Overview of the Pro 1 T705 Programmable Thermostat

The Pro 1 T705 is a programmable thermostat designed for heating and cooling systems‚ offering 7-day or 5/1/1 scheduling. It features a large‚ backlit LCD display for easy readability and intuitive controls. The thermostat supports both battery and hardwired power options‚ ensuring flexibility. With temporary and permanent hold functions‚ users can adjust settings as needed. It also includes a low battery indicator and air filter change reminders. Designed for reliability‚ the Pro 1 T705 is backed by a 5-year limited warranty‚ making it a durable and user-friendly choice for home comfort control.

1.2 Key Features and Benefits

The Pro 1 T705 offers a range of features‚ including 7-day or 5/1/1 programmable scheduling‚ temporary and permanent hold options‚ and an easy-to-read LCD display. It also includes a low battery indicator and air filter change reminders for maintenance convenience. The thermostat supports both battery and hardwired power‚ providing installation flexibility. With its intuitive interface and energy-saving capabilities‚ the Pro 1 T705 enhances home comfort while reducing energy consumption‚ making it a practical and efficient choice for users.

Installation Tips for the Pro 1 T705 Thermostat

Install the thermostat 4-5 feet above the floor‚ avoiding direct sunlight and drafts. Ensure good air circulation and proper wiring connections for optimal performance.

2.1 Wall Location Requirements

The Pro 1 T705 thermostat should be installed on an interior wall‚ approximately 4 to 5 feet above the floor. It must be placed in an area with average room temperature and good airflow to ensure accurate temperature readings. Avoid locations near hot or cold air ducts‚ direct sunlight‚ or exterior walls‚ as these can affect performance. Proper placement is crucial for maintaining consistent heating and cooling system operation.

2.2 Wiring Specifications and Terminal Designations

The Pro 1 T705 thermostat requires shielded or non-shielded 18-22 gauge wires for installation. Key terminal designations include R (24V)‚ W (heating)‚ Y (cooling)‚ G (fan)‚ C (common)‚ and O (heat pump). Ensure correct connections to avoid system malfunction. If replacing an old thermostat‚ note existing wire labels‚ as colors may not match terminal functions. Proper wiring is essential for reliable operation and safety‚ so consult a professional if unsure.

Programming the Thermostat

The Pro 1 T705 allows flexible 5/1/1 or 7-day scheduling with temporary and permanent hold options‚ ensuring precise temperature control and energy efficiency through its intuitive interface.

3.1 Set Program Schedule (5/1/1 or 7 Day)

The Pro 1 T705 offers 5/1/1 and 7-day programmable scheduling‚ allowing users to set specific temperature preferences for different days and times. The 5/1/1 option provides separate settings for weekdays and weekends‚ while the 7-day schedule offers unique settings each day. Users can set up to four programmable periods daily‚ ensuring optimal comfort and energy savings. The thermostat’s menu-driven interface simplifies programming‚ with options to adjust heat and cool setpoints effortlessly. This feature enhances flexibility and customization for varying lifestyles and preferences.

3.2 Temporary and Permanent Hold Features

The Pro 1 T705 offers both Temporary and Permanent Hold features for flexible temperature control. Temporary Hold maintains the current setpoint until the next scheduled period‚ while Permanent Hold keeps the temperature constant indefinitely. To activate Temporary Hold‚ press the ↑ or ↓ keys‚ and the thermostat will display “HOLD” and “RUN SCHED.” For Permanent Hold‚ press the HOLD key‚ and the setpoint will stay until manually adjusted. Pressing “RUN SCHED” exits both holds‚ resuming the programmed schedule. These features provide convenience and customization for user preferences.

Thermostat Operation

The Pro 1 T705 operates with a user-friendly interface‚ featuring a backlit LCD display‚ adjustable setpoints‚ and system/fan switches. It supports cooling‚ heating‚ and fan-only modes efficiently.

4.1 Understanding the Thermostat Interface

The Pro 1 T705 interface features a backlit LCD display‚ showing current temperature‚ setpoints‚ and system status. Buttons include Setpoint arrows‚ Menu‚ and Hold keys. The display also shows indicators like Low Battery‚ HOLD‚ and FILT reminders. A glow-in-the-dark light button provides visibility in low-light conditions. The interface is intuitive‚ allowing users to adjust settings‚ view programming‚ and monitor system operation effortlessly. This design ensures seamless interaction and efficient control of heating and cooling systems.

4.2 System Switch and Fan Switch Functions

The System Switch allows you to select between Heat‚ Cool‚ or Off modes. The Fan Switch offers Auto (runs only when the system is active) or On (continuous fan operation). These switches are located on the thermostat interface for easy access. The System Switch ensures the HVAC system operates in the desired mode‚ while the Fan Switch provides control over air circulation. Together‚ they help customize comfort levels and energy efficiency‚ allowing users to manage their environment effectively.

Advanced Features

The Pro 1 T705 includes a low battery indicator and an air filter change reminder. These features enhance functionality and ensure optimal system performance and energy efficiency.

5.1 Low Battery Indicator and Replacement Guidelines

The Pro 1 T705 thermostat features a low battery indicator that appears when the AA batteries need replacement. Replace batteries promptly to prevent system malfunctions. If ignored for 21 days‚ the thermostat defaults to 55°F (heating) and 85°F (cooling). After 63 days‚ the system shuts off until batteries are replaced. Always use fresh AA batteries to maintain functionality and avoid potential damage to your HVAC system.

5.2 Air Filter Change Reminder and Reset

The Pro 1 T705 thermostat includes an air filter change reminder that displays “FILT” when maintenance is needed. To reset the reminder‚ hold the second button from the top left for 3 seconds. This feature ensures optimal HVAC performance by prompting regular filter replacements. Always change the filter before resetting to maintain system efficiency and indoor air quality. Follow this simple process to keep your system running smoothly and efficiently year-round.

Maintenance Tips

Regular maintenance ensures optimal performance of your Pro 1 T705 Thermostat. Replace batteries when the low battery indicator appears‚ clean the thermostat regularly‚ and check wiring connections. Refer to the manual for detailed procedures.

6.1 Battery Installation and Management

Proper battery management is crucial for the Pro 1 T705 Thermostat. Install two AA alkaline batteries‚ ensuring correct polarity. Replace batteries when the low battery indicator appears. If batteries are not replaced within 21 days‚ the thermostat defaults to 55°F (heating) and 85°F (cooling). After 63 days‚ the system shuts off until batteries are replaced. Always use high-quality batteries to maintain functionality and prevent system failure. Refer to the manual for detailed instructions.

6.2 Avoiding Common Installation Mistakes

Avoid installing the thermostat near hot or cold air ducts‚ direct sunlight‚ or outside walls‚ as this may cause inaccurate temperature readings. Ensure the thermostat is level and securely mounted. Verify wiring connections match the terminal designations‚ especially if replacing an old thermostat. Use 18-22 gauge thermostat wire and avoid loose connections. If unsure‚ consult the manual or contact a professional. Proper installation ensures reliable performance and prevents potential system issues. Always follow the manufacturer’s guidelines for optimal results.

Warranty Information

The Pro 1 T705 thermostat is backed by a 5-year limited warranty. Registration within 60 days of installation is required to activate the warranty period.

7.1 5-Year Limited Warranty Details

The Pro 1 T705 thermostat is covered by a 5-year limited warranty‚ ensuring protection against manufacturing defects. Registration within 60 days of installation is mandatory to validate the warranty. For queries or claims‚ contact the installing HVAC professional or reach out to Pro1 Technologies directly. Proper installation and maintenance are essential to uphold warranty validity‚ ensuring optimal performance and customer satisfaction throughout the covered period.

7.2 Warranty Registration Process

Register your Pro 1 T705 thermostat within 60 days of installation to activate the 5-year warranty. Visit the Pro1 Technologies website‚ navigate to the warranty registration section‚ and complete the online form. Alternatively‚ mail the completed warranty registration form to the provided address. For assistance‚ contact the HVAC professional who installed the thermostat or reach out to Pro1 Technologies at 888-776-1427. Ensure all required information is accurate to avoid delays in processing your warranty registration.

Troubleshooting Common Issues

Check battery levels‚ ensure proper wiring‚ and verify air circulation. Reset the thermostat by holding the reset button for 3 seconds if issues persist.

8.1 Addressing Equipment Damage Hazards

Avoid operating the cooling system if the outdoor temperature is below 50°F (10°C) to prevent compressor damage. Ensure the thermostat is installed away from direct sunlight and hot/cold air ducts. Regularly check and replace batteries to avoid system malfunctions. If the low battery indicator appears‚ replace AA batteries within 21 days to maintain functionality; Failure to do so may result in freezing or overheating. Always follow installation guidelines to prevent equipment damage and ensure optimal performance.

8.2 Resetting the Thermostat and Filter Reminder

To reset the thermostat‚ press and hold the RUN SCHED key for 5 seconds. This restores factory settings while retaining your programmed schedule. For the filter reminder‚ press and hold the second button from the top left for 3 seconds when FILT appears. This resets the reminder after changing the air filter. Regular resets ensure optimal system performance and maintain your heating and cooling efficiency. Always follow these steps to avoid unnecessary interruptions in your HVAC system operation.